Research Article
Methodological Approach for Optimizing Production of Oxygen by Adsorption of Nitrogen from Air using Zeolite Li-LSX
Table 2
Equipment used in the research.
| No. | Device | Specification | Range | Country |
| 1 | Air compressor | Ingco industrial | 0–8 bar | China | 220–240 V, 50 Hz, AC25508 |
| 2 | Pressure gauge with filter unit | D = 2.5 cm | 0–10 bar | China | L = 5 cm | 3 | Feed flow meter | PMB CV.P. A10.LM. G2 | 1–10 L·min−1 | China |
| 4 | Adsorption column | Class type QVF | | | L = 17 cm | iD = 4 cm |
| 5 | Product pressure gauge | | 0–3 bar | China | 6 | Product flow meter | PMB CV.P. A10.LM. G2 | 1–10 L·min−1 | China |
| 7 | O2 gas sensor | GDX-O2 | 0–100% O2 | U. S. | L = 15.5 cm | D = 2.8 cm | 8 | Purge flow meter | Matheson U310 | 0.5–6 L·min−1 | China | 9 | Purge pressure gauge | | 0–3 bar | China | 10 | Valves | | | China |
| 11 | Drum | L = 60 cm | V = 64479.9 cm3 | | D = 37 cm |
|
|