Research Article

Dynamic Simulations of the Allam Cycle Power Plant Integrated with an Air Separation Unit

Table 1

Summary of major stream flow conditions for the air separation unit.

Stream nameMass flow rate (kg/s)Temperature (°C)Pressure (bar)

Air256.1301.013
To Expander25.69.85.9
To LPC25.6−47.83.1
To HPC230.5−1775.9
HX IN187.3−175.95.8
HX OUT187.3−1775.8
LPC TOP 1217.04−190.81.4
LPC TOP 2217.04−188.81.4
LPC BTM39.06−176.21.9
O239.06−19.31.9
N2217.04−22.21.4
NG103830
TO COMB10268330