Research Article
Dynamic Simulations of the Allam Cycle Power Plant Integrated with an Air Separation Unit
Table 1
Summary of major stream flow conditions for the air separation unit.
| Stream name | Mass flow rate (kg/s) | Temperature (°C) | Pressure (bar) |
| Air | 256.1 | 30 | 1.013 | To Expander | 25.6 | 9.8 | 5.9 | To LPC | 25.6 | −47.8 | 3.1 | To HPC | 230.5 | −177 | 5.9 | HX IN | 187.3 | −175.9 | 5.8 | HX OUT | 187.3 | −177 | 5.8 | LPC TOP 1 | 217.04 | −190.8 | 1.4 | LPC TOP 2 | 217.04 | −188.8 | 1.4 | LPC BTM | 39.06 | −176.2 | 1.9 | O2 | 39.06 | −19.3 | 1.9 | N2 | 217.04 | −22.2 | 1.4 | NG | 10 | 38 | 30 | TO COMB | 10 | 268 | 330 |
|
|