Research Article

Six-Year Outcomes of 25-Gauge Chandelier Illumination-Assisted Scleral Buckling

Table 2

Surgical procedures and postoperative clinical characteristics of the 10 cases.

CaseSurgical proceduresLength of band (mm)Size of element (mm)Drainage25G illuminationComplicationsRetinaPostop BCVAFollow-up period (y)BCVA at last follow-up

1360-degree band with element69 mm+Superior nasalNoneAttached20/1005.520/25
2360-degree band with element66 mm+Superior nasalNoneAttached20/4007.320/32
3Element alone mm+Superior nasalNoneAttached20/1006.020/32
4360-degree band with element68 mm+Superior nasalNoneAttached20/257.520/20
5Element alone mm+Superior nasalNoneAttached20/205.820/20
6Element alone mm+Inferior temporalNoneAttached20/505.220/20
7360-degree band with element and sterile air69 mm+Superior nasalNoneNot completely attached20/506.820/25
8Element alone mm+Superior nasalNoneAttached20/325.720/50
9Element alone mm+Inferior temporalNoneAttached20/407.320/20
10360-degree band with element69 mm+Superior nasalNoneAttached20/505.220/25

Element size described by length, width, and thickness; BCVA: best corrected visual acuity.