Maximum classification accuracies of each subject for near-infrared spectroscopy (NIRS), electroencephalography (EEG), and their possible combination (HYB) after onset of task period.

SubjectEEGHbR+EEGHbO+EEGHbR + HbO+EEG

VP00166.886.386.086.784.789.087.5
VP00285.878.286.085.284.884.385.8
VP00388.787.291.587.590.290.593.3
VP00467.582.282.072.277.783.082.5
VP00588.380.888.383.090.082.088.3
VP00696.790.597.385.896.793.598.0
VP00793.886.893.789.594.290.393.7
VP00888.281.889.790.592.089.891.8
VP00961.562.364.574.375.278.377.0
VP01086.883.290.376.790.383.391.2
VP01178.376.579.579.582.078.581.2

Mean82.081.482.885.7
Std11.27.28.45.96.54.95.9