Research Article

The Performance of a New Heuristic Approach for Tracking Maximum Power of PV Systems

Table 4

Normal condition.

MethodIrradiation = 1000 W/m2
Power (W)Time (s)Accuracy (%)

QHBM50.110.89199.9989
mQHBM49.70.82799.97
PSO48.690.83597.38
P&O49.270.90198.54
ANN50.120.82599.9988
GWO49.980.81699.9998
CS49.980.88499.9998