Research Article
Translating Building Information Modeling to Building Energy Modeling Using Model View Definition
Table 3
Material specification.
| Building components | Thermal conductivity (W/m K) | Specific heat capacity (J/kg K) | Mass density (kg/m3) | Thickness (m) |
| Walls | 0.140 | 900 | 530 | 0.100 | Floor | 0.140 | 1200 | 650 | 1.028 | Roof | 0.160 | 840 | 950 | 0.150 |
|
|