Research Article
Pole Allocation Applied to Two Buildings Connected by Joint Damper
Table 6
Damping distributions for models B1, B2, B3, and B4.
| Story | B1 (MNs/m) | B2 (MNs/m) | B3 (MNs/m) | B4 (MNs/m) |
| 10 | 1.226 | 1.498 | 0.785 | 0.959 | 9 | 1.414 | 1.728 | 0.905 | 1.106 | 8 | 1.697 | 2.074 | 1.086 | 1.328 | 7 | 1.980 | 2.420 | 1.267 | 1.549 | 6 | 2.263 | 2.766 | 1.448 | 1.770 | 5 | 2.640 | 3.226 | 1.690 | 2.065 | 4 | 3.017 | 3.687 | 1.931 | 2.360 | 3 | 3.394 | 4.148 | 2.173 | 2.655 | 2 | 3.771 | 4.609 | 2.414 | 2.951 | 1 | 4.148 | 5.070 | 2.655 | 3.246 |
|
|