Research Article

Detection, Localization, and Quantification of Damage in Structures via Artificial Neural Networks

Table 3

Natural frequencies of the 10-bar truss structure (Hz).

ModeFE modelSSI-DATA
Healthy scenarioDamage scenarioHealthy scenarioDamage scenario

1174.9996170.5968174.8116170.4073
2500.6687484.7274496.6709480.9747
3600.8525593.0745593.8417586.3163