Research Article

Study on the Numerical Relationship between Dynamic Compressive Strength and Crushing Energy Consumption in Dynamic Point Load Test under Different Corrosion Conditions

Table 3

Statistical table of dynamic point load test data of samples corroded by salt solution with pH = 2 and pH = 7.

Sample numberpHV (m·s−1) (MPa) (J)

126.5946.7924.62
227.7967.3342.02
328.2674.7648.75
4210.33115.2384.02
5210.79126.3289.22
6213.01167.29122.99
777.3162.0141.02
878.3582.0154.98
979.44105.3170.51
10710.46120.6686.73
11711.87149.68104.02
12712.22158.41109.96