Research Article

Study on the Numerical Relationship between Dynamic Compressive Strength and Crushing Energy Consumption in Dynamic Point Load Test under Different Corrosion Conditions

Table 2

Statistical table of test data on impact compression of samples after corrosion of pH = 2 and pH = 5 solutions.

Sample numberpHV (m·s−1) (MPa) (J)

129.97117.4436.66
2210.76132.3346.33
3211.57149.6952.69
4211.85162.3360.17
5212.74171.1466.32
6213.01210.1774.31
759.77118.3240.84
8510.22130.5443.87
9510.78147.3650.02
10511.23160.1154.73
11512.74184.2670.69
12513.41227.6682.63