Research Article
Time-Series Forecasting of a Typical PWR Undergoing Large Break LOCA
| Parameters | Model | DCD |
| Power, (MWt) | 3,983 | 3,983 | Power peaking factor | 2.2 | 2.258 | RCP flowrate, (kg/s) | 5313.5 | 5250.0 | Core flowrate, (kg/s) | 20326.2 | 20361.0 | Primary pressure, (MPa) | 15.55 | 15.51 | Feedwater temperature, (K) | 505.62 | 505.23 | Safety injection tank coolant volume, (m3) | 52.61 | 52.63 | Safety injection tank gas pressure, (MPa) | 4.31 | 4.25 | Safety injection tank coolant temperature, (K) | 302.59 | 302.5 | IRWST temperature, (K) | 302.45 | 302.5 | Core inlet temperature, (K) | 563.93 | 563.8 | Core outlet temperature, (K) | 607.5 | 597.1 | Upper head temperature, (K) | 563.7 | 584.5 | Pressurizer level, (m) | 7.91 | 8.18 | Secondary pressure, (MPa) | 6.89 | 6.86 |
|
|