Research Article
Accuracy Evaluation of Monte Carlo Simulation Results Using ENDF/B-VIII.0 and JENDL-5 Libraries for 10 MWth Micro Heat Pipe-Cooled Reactor
Table 1
Main parameters of the 10 MWth MHPR core.
| Parameters | Value |
| Total power (MWth) | 10 MWth | Active height (cm) | 100 | Upper/lower reflector (cm) | 30 | Core diameter (d, cm) | 250 | Active core pitch (cm) | 101 | Fuel type | UO2 (19.75% enrichment) | Fuel volume (cm3) | 205,944.1 | Operating temperature (K) | 1200 | Number of heat pipes | 2376 | Heat pipe inner diameter (cm) | 1.575 | Heat pipe wick diameter (cm) | 1.757 | Heat pipe wall diameter (cm) | 1.857 | Heat pipe-to-heat pipe pitch (cm) | 2.024 | Reflector material | BeO |
|
|