Loading conditions of shaking table test.

Test numberModel I (with water)Model II (without water)
Frequency (Hz)Frequency variation (%)Frequency (Hz)Frequency variation (%)

116.5119.89
416.49−0.1219.88−0.05
716.49−0.1219.85−0.20
1016.47−0.2419.81−0.40
1316.45−0.3619.78−0.55