Research Article
Experimental and Numerical Studies of AP1000 Shield Building considering Fluid-Structure Interaction
Table 4
Loading conditions of shaking table tests.
| Test number | Ground motion | PGA (g) | Test duration (s) |
| 1 | White noise | 0.05 | 10.00 | 2 | Scaled El Centro ground motion | 0.10 | 7.54 | 3 | Scaled artificial ground motion | 0.10 | 10.00 | 4 | White noise | 0.05 | 10.00 | 5 | Scaled El Centro ground motion | 0.15 | 7.54 | 6 | Scaled artificial ground motion | 0.15 | 10.00 | 7 | White noise | 0.05 | 10.00 | 8 | Scaled El Centro ground motion | 0.20 | 7.54 | 9 | Scaled artificial ground motion | 0.20 | 10.00 | 10 | White noise | 0.05 | 10.00 | 11 | Scaled El Centro ground motion | 0.30 | 7.54 | 12 | Scaled artificial ground motion | 0.30 | 10.00 | 13 | White noise | 0.05 | 10.00 |
|
|