Comparison of peak strain between test and simulation.
| PGA (g) | Ground motion | Acceleration number | Peak strain of test () | Peak strain of simulation () | Relative error (%) |
| 0.30 | Scaled El Centro ground motion | S6 | 61.28 | 57.64 | −5.94 | S7 | 48.10 | 45.17 | −6.09 | S8 | 37.14 | 35.02 | −5.71 | S9 | 26.87 | 24.94 | −7.18 |
|
|