Research Article
Impact of Strontium and Krypton Release from Ghana’s MNSR following a Conjectural Accident Scenario
Table 5
Total effective dose and other plume centerline parameters at different arrival times.
| Distance (Km) | TEDE for Sr-90 (Sv) | TEDE for Kr-85 (Sv) | Ground surface deposition for Sr-90 (KBq/m2) | Arrival time (hour : min) |
| 0.100 | 1.8E − 05 | 4.9E − 07 | 4.6E − 01 | 00 : 01 | 0.200 | 9.9E − 06 | 2.9E − 07 | 2.5E − 01 | 00 : 03 | 0.300 | 5.0E − 06 | 1.5E − 07 | 1.3E − 01 | 00 : 05 | 0.400 | 2.9E − 06 | 8.9E − 08 | 7.5E − 02 | 00 : 07 | 0.500 | 1.9E − 06 | 5.9E − 08 | 4.8E − 02 | 00 : 09 | 0.600 | 1.3E − 06 | 4.2E − 08 | 3.4E − 02 | 00 : 11 | 0.700 | 9.6E − 07 | 3.1E − 08 | 2.5E − 02 | 00 : 13 | 0.800 | 7.3E − 07 | 2.4E − 08 | 1.9E − 02 | 00 : 13 | 0.900 | 5.8E − 07 | 1.9E − 08 | 1.5E − 02 | 00 : 17 | 1.000 | 4.7E − 07 | 1.6E − 08 | 1.2E − 02 | 00 : 019 |
|
|