Research Article
Analysis on Steady-State Operation and Heat Loss of Chinese Integrated Pressurized Water Reactor
Table 1
Comparison of calculation results between package subroutine and IAPWS-IF97.
| Region | Parameters | Given by | (kJ kg−1) |
| Region 1 | = 300 K | IF97 | 115.331273 | = 3 MPa | Package | 115.33127302 | = 300 K | IF97 | 184.142828 | = 80 MPa | Package | 184.14282773 |
| Region 2 | = 300 K | IF97 | 2549.91145 | = 0.0035 MPa | Package | 2549.9114508 | = 2000 K | IF97 | 6571.22604 | = 30 MPa | Package | 6571.2260386 |
|
|