Research Article

Survey on Reversible Watermarking Techniques of Echocardiography

Table 2

Embedding results with variant sizes of ROI.

2K6K10K
ROI sizePayload (bits)Capacity of hiding (bpp)PSNRPayload (bits)Capacity of hiding (bpp)PSNRPayload (bits)Capacity of hiding (bpp)PSNR

Ultrasound 1
4%169,4240.28737.01209,5200.35436.42246,7680.41736.07
8%260,7040.44135.99299,7600.50735.54335,3120.56735.28
12%395,6800.66935.63436,5280.73835.60n/an/an/a

Ultrasound 2
4%155,8080.26437.46194,8160.32936.81230,1120.38936.46
8%245,3760.41536.45283,8720.48036.09319,0240.53935.86
12%376,3680.63636.13417,0560.70536.09n/an/an/a

Ultrasound 3
4%122,8480.30341.88163,1360.40240.13200,1760.49439.15
8%207,7760.51239.36245,8240.60638.34281,2000.69437.75
12%263,9840.65138.24n/an/an/an/an/an/a

Ultrasound 4
4%82,8320.27041.25119,0880.38839.81153,9680.50138.57
8%151,5520.49338.84191,0240.62237.94n/an/an/a
12%190,9120.62238.10n/an/an/an/an/an/a