Research Article

Development of a Digital Twin Framework for a PV System to Resolve Partial Shading

Table 3

Irradiation pattern before and after reconfiguration with position vector and power difference.

Case no.Initial panel positionNumber of peaksIrradiation pattern (W/m2)Position after reconfigurationNo. of peaks after reconfigurationPower difference at first peak (W)Power difference at global peak (W)

11 4 731000 1000 10005 3 91+73 W+42 W
2 5 81000 1000 02002 7 8
3 6 91000 0200 02004 1 6

21 4 721000 1000 10002 9 51+14 W+14 W
2 5 81000 1000 05004 3 7
3 6 91000 0200 05008 6 1

31 4 731000 1000 10006 2 52+46 W+30 W
2 5 81000 1000 05009 1 4
3 6 91000 0500 02008 3 7
3

41 4 731000 1000 10009 4 5−7 W+18 W
2 5 80500 0500 10008 7 3
3 6 90200 0200 10001 2 6

51 4 731000 1000 05008 4 51+54 W+32 W
2 5 81000 0500 02009 1 3
3 6 90500 0200 02004 2 7

61 4 731000 1000 10008 6 11+45 W+38 W
2 5 80500 0500 05005 9 4
3 6 90200 0200 02002 3 7