Abstract

This research intends to numerically study the out-of-plane behaviour of confined dry-stacked masonry (CDSM) walls against blast loading. CDSM is a mortarless interlocking masonry system consisting of Hydraform blocks laid in stretcher bond with reinforced concrete (RC) confining elements. A nonlinear numerical model is developed using advanced finite element hydrocode ANSYS-Autodyn to study the response of CDSM walls subjected to explosive loads. Four different test cases using a charge weight of 4 kg, 8 kg, 12 kg, and 16 kg of Wabox explosive are investigated numerically. The results obtained from numerical simulation are validated with the experimental tests results. The numerical results are found in good agreement with the experimental results. The ability of the numerical model is studied to correctly predict the pressure-time history in pressure gauges installed on walls and compared with experimental data. Peak incident overpressures obtained in these numerical tests ranged from 240 to 1000 kPa. Likewise, the damage patterns obtained from the numerical simulations are compared with available experimental results which show a satisfactory agreement. This study helps to check the response of CDSM structures against blast load which can be used for the construction of blast resisting design of buildings.

1. Introduction

Terrorism, after 9/11 in Pakistan, has become a devastating and extremely harmful phenomenon. The human losses are more than 70,000 and with economic cost of more than $68 billion [1]. Terrorists mostly hit government lifeline structures such as educational institutes, healthcare facilities, police and army installations, and government infrastructures by bomb blasts which are mainly built from masonry [2]. In these scenarios, the performance of masonry walls is very critical for the structural integrity of buildings. It is very challenging to study experimentally the effects of blast load on structures due to numerous input parameters, limited financial resources, time constraints, and safety considerations. Therefore, the best alternative for such type of costly experiments is an efficient computer software and codes such as ANSYS-Autodyn [3].

Besides conventional masonry, a new masonry system of mortarless interlocking blocks, which is also known as dry-stack masonry, has recently been introduced in Pakistan. The typical shape of dry-stack masonry blocks (Hydraform blocks) and their masonry assemblage is shown in Figure 1. If this masonry system is confined by reinforced concrete (RC) beam and columns, then it is termed as confined dry-stack masonry (CDSM) system. The CDSM system was found to be more ductile and reliable in strength for lateral loads [4]. The structural strength and integrity of this masonry system depend on interlocking system of blocks between masonry units. The interlocking mechanism provides stability, self-alignment, and levelling to the walls. Hydraform blocks are manufactured from mixture of soil with at least 22% clay, 10% sand, and 6.7% cement by weight mixed using a cement mixer. Approximately, 10% water is added to the mixture to achieve the desired consistency for block pressing and after seven days of curing, it is used in constructing walls [5]. The construction process in this type of masonry is simplified and highly economically competitive due fast track construction and very effective where skilled labor is expensive and even unavailable. Being a sustainable building material, it is more energy efficient compared to traditional clay-bricks which require three times more energy per square metre (406 kg of CO2 emission) than Hydraform blocks (119 kg of CO2 emission) [6].

The numerical modelling of CDSM walls is complex and computationally expensive. The analysis complexity reasons are modelling of the nonlinear behaviour of an RC confining frame, modelling of the nonlinear behaviour of a dry-stacked masonry panel, and modelling the interaction between frame and masonry [7].

Several researchers in the past have studied the blast load phenomenon on various structures numerically and experimentally such as Luccioni et al. [8] who conducted a numerical study to analyse the structural failure of the reinforced concrete building under the blast load. The results were compared with actual buildings that were damaged in terrorist attacks. In another study [9], the same researcher performed numerical analysis of blast load using hydrocodes and compared the results with empirical models with a good correlation. Theobald and Nurick [10] performed numerical and experimental study to investigate the performance of tube-core claddings under blast loads. A numerical model was developed in computer program ABAQUS/Explicit for numerical simulations which shows satisfactory correlation with experimental response. Thiagarajan et al. [11] conducted numerical and experimental study to investigate the performance of doubly reinforced concrete slabs against the blast loads. They employed the commercial program LS-DYNA for numerical simulations, and their numerical and experimental results were matched with a good agreement. Wu et al. [12] conducted a 3D and 2D numerical study by using commercial software Autodyn3D for the analysis of infilled masonry in RC frame structures subjected to ground excitations induced by blast waves. After comparison of results, they concluded that 3D analysis captured the real response of the structures. Ghaderi et al. [13] in 2015 used ABAQUS as numerical analyses tools to represent unreinforced brick masonry walls strengthened with 1.5 mm thick FRP strips fixed in various formations and subjected to a blast load based on scale-distance parameter. Finally, they observed more damage to wall as the scale-distance decreased. Scaled distance (z) is parameter used for the intensity level of blast load as defined by equation (1), established by Hopkinson and Cranz [14], which relate charge weight of equivalent TNT (W) and standoff distance (R).

Alsayed et al. [15] in 2016 carried out blast load tests on block masonry wall specimen confined by a frame of reinforced concrete. They conducted five tests of various charge size and standoff displacements in the field. In conclusion, they found that the numerical results, obtained from ANSYS-Autodyn, best matched for the blast load parameters such as arrival time, peak incident, and peak reflected overpressures and therefore, the numerical techniques are the valid way to analyse the walls against blast load. Edri and Yankelevsky [16] in 2018 considered a new analytical model for the dynamic response in terms of time-displacement history of one-way arching URM walls under blast loads. Their SDOF model predictions have shown good agreement after comparisons with experimental test results. Michaloudis and Gebbeken [17] in 2019 presented in their study a modelling strategy appropriate for masonry walls subjected to far-field and contact detonations blasts to capture the local damage and debris formation. They adopted a derived material model for brick masonry from a concrete model which was already tested under blast load. Their proposed model shows good performance and combines the advantages of fully Lagrangian approaches and Smoothed Particle Hydrodynamic (SPH) approach. The delivered numerical results of the model were in good agreement with the result of experimental studies. It is concluded from abovementioned discussion that most of the recent research studies have focused on the performance evaluation of conventional masonry and RC structures while research on CDSM structures performance against blast load is limited.

The aim of this research study is to develop a 3D finite element model to systematically study the out-of-plane behaviour of CDSM wall against blast load. A full-scale CDSM wall was developed in ANSYS-Autodyn and tested against the blast loads generated from Wabox explosive. The numerical simulations were performed for different test cases. Finally, the results obtained from numerical analysis were compared with the data obtained from experimental tests conducted by Ullah [18] on the same masonry wall.

2. Description of CDSM Test Wall

The considered test model in this research is a CDSM wall shown in Figure 2, which is representative of typical masonry buildings constructed in Pakistan. The CDSM wall tested in the field by Ullah [18] and the same wall was modelled in the ANSYS-Autodyn. The CDSM wall panel is 7 ft (2.134 m) tall, 7 ft (2.134 m) wide, 8 inch (200 mm) thick confined by confining elements of 8 inch × 8 inch (200 mm × 200 m) with typical 4-#4 (4φ12 mm) steel longitudinal reinforcement and #3 (φ10 mm) rings provided at 6 inch (150 mm) center-to-center distance. All the steel rebars used in the wall specimen are tested and are of 40,000 psi (420 MPa) strength. Concrete cylinder specimens were casted during construction of test wall and tested for compressive strength after 28 days of curing. On average, compressive strength of 3000 psi (20.70 MPa) was obtained for ordinary concrete. The Hydraform blocks available in the local market of size 8 inch × 8 inch × 4 inch (200 mm × 200 mm × 100 mm) have been used to construct wall specimens. The gross area compressive strength of Hydraform block is 1940 psi (13.25 MPa) whereas based on shoulder area it is 1240 psi (8.50 MPa). As the stress transfer in dry-stacking condition is only through shoulders of the block, masonry prisms tested in the laboratory by applying load on the shoulders and the compressive strength of masonry were calculated as 730 psi (5.00 MPa). The Elastic Modulus from prism test was calculated as 606,660 psi (4182.77 MPa). All the test results are adopted from the research study of Hafeez [19]. The cement mortar with mix proportion of (1 : 6) has been used in the construction of starter course of the masonry walls.

3. Description of Testing Setup

Wabox (TNT equivalent = 1.1) explosive is used in this research study for blasting which is a nitroglycerine-based dynamite manufactured by WA Nobel PVT Ltd. Rawalpindi, Pakistan. The charge of Wabox explosive is situated 3 ft (915 mm) above the ground at a distance of 12 ft (3.66 m) from the wall as shown in Figure 3. Three pressure gauges G-01, G-02, and G-03 are installed on the windward face of the wall. The pressure gauges are installed to measure the incident overpressures on the face of the wall.

Four blast tests on the same CDSM wall, namely, blast tests #1, #2, #3, and #4, with varying charge weight were conducted in field by Ullah [18] carried out in Risalpure (Nowshera), Pakistan, and the same tests were modelled in ANSYS-Autodyn for calibration. In these tests, the wall was subjected to four blast load tests with increasing level of intensity and scale-distance parameter has been used for intensity level measurement; details are listed in Table 1.

4. Material Models for Simulations

ANSYS-Autodyn is a hydrocode which uses fundamental law of physics such as law of conservation of mass, momentum, and energy in the form of partial differential equations (PDEs). These governing PDEs including initial and boundary conditions are used to predict the response of the system materials for large deformation in nonlinear dynamic problem. The mathematical relationships between density, pressure, internal energy, stresses, and strains are required for this analysis. These relationships are equation of state (EOS), strength constitutive model, and failure criteria for each material component. The following subsections provide the details of the material models and parameters used for numerical analysis.

4.1. Material Model for Air

In this study, the strength models and failure criteria models are not required as it is air blast and these parameters are usually required in undermining blast experiment. The following equation of state (EOS), as given by equation (2), is used for the air as it was assumed that the surrounded air is an ideal gas.

Here, p is the pressure, γ is the constant of adiabatic process, which is estimated to be 1.4 for ideal gas, ρ is the specific mass, and e is the specific internal energy of the air. The parameters values of ideal gas EOS are listed in Table 2, which are adopted from ANSYS-Autodyn material library.

4.2. Material Model for Wabox Explosive

The Jones-Wilkins-Lee (JWL) [20] equation of state is formulated for the modelling of Wabox explosive material. JWL equation of states correlates chemical properties such as energy, volume, and pressure of high energy explosive products. The JWL equation of state in mathematical form is given bywhere A, B, R1, R2, ω are derived empirical constants which have different values for different explosive materials, V define the expansion of the detonating materials, and e is the specific energy at detonation stage.

The input parameters values of the JWL equation of state used for Wabox explosive (TNT equivalent = 1.1) are taken from Abbas et al. [21] and remaining properties are available in ANSYS-Autodyn which are summarised in Table 3. In this study, the Eulerian solver (multimaterial) was employed for modelling both air and explosive material.

4.3. Material Model for Reinforced Concrete

In this study, the Riedel–Hiermaier–Thoma (RHT) material model of Riedel et al. [22], implemented in ANSYS-Autodyn, has been used for reinforced concrete. This model is extensively used for concrete and brittle materials to predict their response under blast load. In the RHT model for concrete, the two basic parameters, compressive strength (fc) and tensile strength (ft) obtained from uniaxially loaded cylinder test, are required. The remaining parameters of concrete are derived from these parameters. The concrete strength in RHT is controlled by three strength failure surfaces: initial surface also called elastic limit surface, failure surface, and postfailure surface (residual surface) as shown in Figure 4. In this model, high tensile strength of concrete has been adopted to incorporate the tensile strength of mild steel reinforcement bars based on the study of Luccioni et al. [8]. Therefore, modified properties of reinforced concrete, as listed in Table 4, have been used.

Based on the hydrostatic behaviour of porous concrete the RHT model utilizes the pα equation of state (EOS) model of Herrmann [23]. EOS is a function that mathematically correlates hydrostatic pressure, specific volume, and internal energy. This equation of state model is adopted in this research to capture the key global response of the wall. The input parameter values, that define the p-α equation of state, are adopted from ANSYS-Autodyn materials library which are listed in Table 4.

4.4. Material Model for Dry-Stack Masonry

In numerical modelling, masonry walls can be modelled using either micro- or macromodel. Micromodel is distinctive simulation of masonry while macromodel is a homogenized simulation. In this study, homogenized macromodel is used for masonry wall to characterize Hydraform blocks and joints properties [2428]. The use of macromodelling for masonry substantially optimises the computational time and cost for simulation. Therefore, it can be efficiently employed when microscopic response is not important like in case of extreme loads [29]. In this study, dry-stack masonry was modelled as homogenous low-strength concrete as the wall is constructed from concrete Hydraform blocks. The mechanical properties of Hydraform blocks and dry-stack masonry are taken from Hafeez [19] and the remaining input parameters are adopted from ANSYS-Autodyn material library which are listed in Table 5.

5. Finite Element Model Parts

The finite element model was developed in the software which is composed of CDSM wall and air volume by the wall. Due to symmetry, only half of the physical air domain and wall was modelled to reduce the computation costs. The model for CDSM wall is developed with three different Lagrangian parts, i.e., RC footing, confining elements, and dry-stack masonry wall. The 8-noded hexahedral solid elements of size 50 mm have been used in all three Lagrangian parts. Figure 5 illustrates the finite element meshing grid of the model, pressure gauge’s location, and detonation. In this model, a fixed boundary condition was adopted by using unbreakable connection between the confining frame and footing, whereas stress-criteria based breakable connections were assumed between the masonry and confining frame. The details of input parameters for breakable connection are listed in Table 6.

The surrounded air part of the model was modelled as Eulerian, ideal gas. A three-dimensional (3D) domain of cuboid-shaped was created for surrounded air. The sizes of surrounded air domain are 4.22 × 2.40 × 2.20 m. The element dimension for air volume is used as 25 mm which is an optimised size based on mesh convergence studies.

6. Erosion Criteria

As per the study carried out by researcher [32, 33], the elements of the reinforced concrete confining frame were permitted to erode from the system when the level of geometric strain (instantaneous) reaches 0.5. But dry-stack masonry geometric strain (instantaneous) of 0.02 was assumed as a criterion for the erosion of wall elements. These erosion models are adopted in ANSYS-Autodyn to avoid extreme and impractical deformation of mesh or grid system and also to model the fragmentation of wall parts.

7. Blast Analysis in ANSYS-Autodyn

The blast load analysis of the CDSM wall in ANSYS-Autodyn was performed in two phases. The first phase, which is a one-dimension (1D) analysis, simulates the early-stage time expansion of blast wave in 1D using radial symmetry. This expansion of pressure wave continues until it hits the reflecting boundary. In the second phase, the output of the 1D analysis is then transferred to the 3D domain which is created independently. In this study, the explosive material is installed at 0.92 m above the ground surface. Therefore, it is considered as air blast and ground shocks are ignored due to its negligible effects.

7.1. 1D ANSYS-Autodyn Analysis

In 1D analysis, the expansion of blast wave, generated after the explosive detonation of material in the surrounding air, was first modelled and simulated. The problem in this stage can be treated as one-dimensional (1D) due to spherical symmetry, and a wedge is defined for the problem domain. The wedge geometric dimensions are specified on the basis of mass of explosive material and standoff distance. The finite element model of the wedge for the blast test of 16 kg Wabox at 3.66 m standoff distance is shown in Figure 6. The inner radius of the wedge is kept equal to 1 mm to avoid the zero thickness of the element at the origin. However, when this correction is employed, it reduces the weight of the explosive material, but its effect is insignificant due to small percentage reduction. The wedge model is filled with explosive material and surrounding air. The dimension of the elements in wedge is taken as 2 mm for achieving the desired level of accuracy and less computational time [34].

The output of this 1D analysis was later remapped in 3D domain of the model which was developed separately. The 3D domain of the model represents the wall with occupied air volume. This remapping technique reduces drastically the computational time and cost of the analysis. Figure 6 shows the plot of pressure contours at the end of the 1D analysis for 16 kg Wabox at 3.66 m standoff distance. The 1D blast analysis was carried out for four different scaled distances covering different charge weight of blast tests.

7.2. 3D ANSYS-Autodyne Analysis

The 1D analyses results were remapped onto the 3D domain already modelled with wall and surrounded air, separately. During remapping process, the center position of explosive charge from wall, that is, its standoff distance and height from ground, is defined in the remap dialogue box of ANSYS-Autodyn. In 3D analysis, fully coupled simulation was assumed between Lagrangian parts and air. The pressure waves at the start of the 3D analysis for 12 kg Wabox test are shown in Figure 7. All the foundation element nodes were assigned zero translational velocities which simulates fixed boundary condition for the wall at ground level. In ANSYS-Autodyn, Eulerian boundaries adopt reflecting boundary condition by default unless the specified boundary condition is assigned. Therefore, flow-out boundary condition was first defined in ANSYS-Autodyn and then assigned to the outer surfaces of all air domain. The flow-out boundary condition allows the exit of pressure waves from 3D air domain outer surfaces without reflection of pressure waves back to the domain [35]. Moreover, the terminal time for the analysis was kept as 50.0 ms for the blast traveling time between detonation point and wall. For the complete analysis and response investigation of the wall specimen, this time is considered enough and appropriate.

8. Results and Discussion

A total of four charge weights detonations were simulated, of 4 kg, 8 kg, 12 kg, and 16 kg of Wabox explosive material. Furthermore, the gauge installed at mid locations was considered for pressure-time history as per availability of the experimental data. The analysis of explosive detonation and CDSM response was carried out using software ANSYS-Autodyn. The comparison of the results obtained from ANSYS-Autodyn was made with experimental data from Azmatullah [18] for pressure-time history and damage pattern which will be discussed in the coming sections.

8.1. Pressure-Time History

The pressure-time history comparisons between the experimental data and numerical simulation resulting from 4 kg, 8 kg, 12 kg, and 16 kg Wabox explosive detonation are shown in Figure 8. Minor discrepancies have been observed in Figure 8 between the numerical simulation and experimental graphs. Experimental graphs of pressure-time history display some roughness in curves while smooth pressure profile has been obtained from the numerical simulation. Moreover, the pressure peaks and arrival time do not match by small margin. These minor differences are mainly due to the reflection effects of blast waves from ground, which can be detected by pressure sensors installed on the wall. These miner reflections were not considered in the ANSYS-Autodyn model. However, there is still a general agreement between the pressure profiles of the numerical simulation and experimental tests. This validates that the numerical simulation in ANSYS-Autodyn is a reliable alternative for blast load tests on structures. From these graphs a comparison of incident overpressure and arrival time is illustrated in the coming subsections. The results were also calibrated with empirical model developed by Kingery-Bulmash [36] for incident overpressure and arrival time. The Kingery-Bulmash equations have also been automated in the computer program CONWEP used for analysis of blast load.

8.1.1. Comparison of Peak Incident Overpressure

The summary of incident peak overpressure for different scaled distances obtained from ANSYS-Autodyn, experimental tests by Ullah [18], and Kingery-Bulmash model is given in Table 7 and is also plotted in Figure 9.

It is observed from Figure 9 that pressure variation trend for the three different model is nearly the same. The incident pressure values are also in close range except for the near field blast (z = 1.41 m/kg1/3).

8.1.2. Comparison of Arrival Time

Summary of results in terms of arrival time obtained from ANSYS-Autodyn, experimental tests, and Kingery-Bulmash empirical model is listed in Table 8.

The results comparison chart, as illustrated in Figure 10, displays the variation in arrival time values. However, the arrival time obtained from all three sources still shows a good correlation with slight variation which can be ignored for such type of large deformation or strain phenomenon.

8.2. Damage Pattern of Wall

The validation of the ANSYS-Autodyn 3D results with the experimental tests conducted by Ullah [18] was carried out through damage or failure pattern. The failure pattern is based on the damage level contours obtained from numerical analysis at the end of each simulation which shows damage zones of the specimen. The numerical values for damage level contour ranges from 0.0 to 1.0 which represents no damage and full damage, respectively. The failure pattern obtained from the numerical simulation shows a good correlation with the experimental results as illustrated in the coming sections.

8.2.1. Damage Pattern of Blast Test #1

In the first blast test, the CDSM wall was subjected to a blast of 4 kg explosive of Wabox at an altitude of 0.92 m and standoff distance of 3.66 m. This blasting test of scaled distance, 2.23 m/kg1/3, was of very low intensity; therefore, no damage has been observed to the wall as shown in Figure 11. After that, higher level intensity blast has been applied to the same wall specimen in the second blast which was named as blast test (#2).

8.2.2. Damage Pattern after Blast Test #2

It was found that for wall after 8 kg Wabox Blast (scaled distance of 1.77 m/kg1/3) minor cracked are observed at the interface of the masonry and confining frame as shown in Figure 12, which confirms the experimental result. The damage was minor; therefore, the same wall was used for the third blast test.

8.2.3. Damage Pattern after Blast Test #3

Further damage was observed and the cracks between confining element and masonry interface were increased after 12 kg (scaled distance of 1.55 m/kg1/3) blast. However, for the wall specimen with increased intensity level of blast load, the wall was still intact, and no global failure has been observed. This result also shows a good comparison with the experimental results as shown in Figure 13.

8.2.4. Damage Pattern after Blast Test #4

In the final 16 kg Wabox explosion (scaled distance of 1.41 m/kg1/3), the CDSM wall was completely damaged due to joint failure of the confining elements. The experienced damage level was high due to the debonding of the confining elements and blocks of the wall. This result also shows good conformance with the experimental test as shown in Figure 14. Although the left joint of the confining frame is intact, the right side joint failed by stress concentration which may be due to poor construction.

Based on the above simulations, a decent correlation has been attained between the obtained damage patterns of numerical analysis and field experiments of all four blast tests on the CDSM wall. This shows the validity of the numerical modelling analyses in capturing the real behaviour of CDSM wall exposed to blast loads.

9. Conclusion

Four different test cases of explosive charge detonation and blast wave propagation in open space on CDSM wall were investigated numerically using ANSYS-Autodyn software. From this numerical simulation study, the following were concluded.(i)The complex wave structure of blasts was analysed and pressure-time history records on walls were described and compared with experimental records which shows good agreement.(ii)The incident overpressure and arrival time values obtained from pressure-time history records were compared with experimental data and empirical models for calibration. The numerical model output values show good correlation with experimental and empirical models.(iii)The numerical analysis is able to predict damage pattern with reasonable accuracy. Thus, the obtained damage patterns for each test were compared with experimental damage map which shows good correlation. Therefore, this numerical model can also be employed for parametric study on CDSM walls.(iv)It is observed from the results of numerical analysis that the out-of-plane flexure capacity of CDSM walls against blast loads has been increased by providing proper confining elements. This also confirms the response of CDSM walls observed in the experimental tests conducted in the field.

Data Availability

The simulation data used to support the findings of this study are included within the article.

Conflicts of Interest

The authors declare that there are no conflicts of interest regarding the publication of this study.

Acknowledgments

The work was financially supported by the Higher Education Commission, Islamabad, Pakistan (Project code: TDF-(02-038)), for executing scientific activities in the country. The authors are grateful to ECO Enterprises for providing the concrete blocks and financial support.