Research Article
Correction Method for Hydraulic Conductivity Measurements Made Using a Fixed Wall Permeameter
Table 2
Summary of corrected hydraulic conductivities against observed values for confined soil bed.
| No. | D (mm) | d (mm) | E | emax | emin | ξ | α | eb | λ | kc (cm/s) | Test results [20] | Correction value | kt (cm/s) | (%) | (cm/s) | (%) |
| 1 | 50.8 | 4.00 | 0.590 | 0.786 | 0.372 | 3.225 | 1.192 | 1.688 | 0.181 | 7.28 | 11.60 | 59.3 | 6.83 | 6.2 | 2 | 50.8 | 2.80 | 0.572 | 0.786 | 0.372 | 3.256 | 1.177 | 1.635 | 0.129 | 4.00 | 5.68 | 42.0 | 3.76 | 6.0 | 3 | 50.8 | 1.70 | 0.565 | 0.786 | 0.372 | 3.269 | 1.171 | 1.585 | 0.079 | 1.82 | 2.37 | 30.2 | 1.81 | 0.5 |
|
|