Research Article

NPC Three-Level Inverter Open-Circuit Fault Diagnosis Based on Adaptive Electrical Period Partition and Random Forest

Table 5

Accuracy of fault identification for different models.

Diagnosis methodCase 1 accuracy rateCase 2 accuracy rate

SVM95.38%95.91%
93.07%95.65%
96.59%97.28%
KNN85.52%87.98%
86.68%87.56%
89.36%91.28%
RF-proposed99.21%99.38%