NPC Three-Level Inverter Open-Circuit Fault Diagnosis Based on Adaptive Electrical Period Partition and Random Forest
Table 5
Accuracy of fault identification for different models.
Diagnosis method
Case 1 accuracy rate
Case 2 accuracy rate
SVM
95.38%
95.91%
93.07%
95.65%
96.59%
97.28%
KNN
85.52%
87.98%
86.68%
87.56%
89.36%
91.28%
RF-proposed
99.21%
99.38%