Research Article

Planar Sensor for Material Characterization Based on the Sierpinski Fractal Curve

Table 2

Comparison between different sensors.

ReferenceMethodsSpecifications
Freq (GHz)Q-factorS-parameter (dB)Sensitivity

[20]Circular split ring resonator3.68409-35.0 (S21)39.1
[21]Omega shape resonator1.912-6.0 (S21)ā€”
[18]Rectangular open-loop resonator2.13143-26.1 (S11)48.8
This work (third pole)Sierpinski fractal curve resonator4.13445.23-20.6 (S11)70.3

Estimated.