Research Article
Research and Application of Heavy-Equipment Parachute Rope Tension Sensor
Table 2
Temperature error of the sensor with compensation.
| Tension (kN) | V out (V) | Errtemp (%FS) | −20°C | −10°C | 0°C | +10°C | +20°C | +30°C | +40°C |
| 0 | 0.041 | 0.032 | 0.028 | 0.022 | 0.019 | 0.021 | 0.043 | 0.48% | 20 | 0.998 | 1.005 | 1.007 | 1.010 | 1.011 | 1.014 | 1.019 | 0.26% | 40 | 1.964 | 1.973 | 2.002 | 1.997 | 2.006 | 2.004 | 2.000 | 0.84% | 60 | 2.932 | 2.961 | 2.958 | 2.971 | 2.975 | 2.982 | 2.973 | 0.86% | 80 | 3.905 | 3.913 | 3.912 | 3.924 | 3.925 | 3.928 | 3.930 | 0.40% | 100 | 4.875 | 4.863 | 4.857 | 4.867 | 4.862 | 4.870 | 4.881 | 0.38% |
|
|