Clinical Outcomes with Extended Depth of Focus Intraocular Lenses in Cases in Which Multifocal Lenses Are Not Primarily Recommended
Table 2
Visual outcomes obtained in the retrospective phase of the current study according to the condition for which multifocal IOL implantation was not recommended. Abbreviations: SD, standard deviation; IOL, intraocular lens; CDVA, corrected visual acuity; CNVA, corrected near visual acuity.
Condition
Preoperative
Postoperative discharge visit
N
Mean (SD)
N
Mean (SD)
-value
Range
Range
LogMAR CDVA
Fellow eye with monofocal IOL
10
0.30 (0.22)
10
0.05 (0.10)
<0.001
0.05 to 0.70
0.00 to 0.32
Previous vitrectomy
3
0.24 (0.19)
3
0.06 (0.04)
0.03 to 0.40
0.03 to 0.10
Mild maculopathy
8
0.18 (0.16)
8
0.09 (0.07)
0.185
0.03 to 0.52
0.03 to 0.22
Age > 75 years
10
0.30 (0.16)
10
0.09 (0.10)
0.002
0.05 to 0.52
0.00 to 0.32
Amblyopia
2
0.22 (0.00)
2
0.22 (0.00)
0.22 to 0.22
0.22 to 0.22
LogMAR CNVA
Fellow eye with monofocal IOL
7
0.22 (0.18)
8
0.04 (0.05)
0.040
0.10 to 0.52
0.00 to 0.10
Previous vitrectomy
1
0.40 (0.00)
3
0.03 (0.06)
0.40 to 0.40
0.00 to 0.10
Mild maculopathy
7
0.24 (0.17)
7
0.13 (0.06)
0.053
0.10 to 0.52
0.10 to 0.22
Age > 75 years
8
0.27 (0.18)
8
0.11 (0.04)
0.020
0.10 to 0.52
0.10 to 0.22
Amblyopia
2
0.22 (0.00)
2
0.22 (0.00)
0.22 to 0.22
0.22 to 0.22
Not enough sample size to provide statistical analysis.