Abstract

Graphene channel liquid container field effect transistor pH sensor with interdigital microtrench for liquid ion testing is presented. Growth morphology and pH sensing property of continuous few-layer graphene (FLG) and quasi-continuous monolayer graphene (MG) channels are compared. The experiment results show that the source-to-drain current of the graphene channel FET has a significant and fast response after adsorption of the measured molecule and ion at the room temperature; at the same time, the FLG response time is less than 4 s. The resolution of MG (0.01) on pH value is one order of magnitude higher than that of FLG (0.1). The reason is that with fewer defects, the MG is more likely to adsorb measured molecule and ion, and the molecules and ions can make the transport property change. The output sensitivities of MG are from 34.5% to 57.4% when the pH value is between 7 and 8, while sensitivity of FLG is 4.75% when the . The sensor fabrication combines traditional silicon technique and flexible electronic technology and provides an easy way to develop graphene-based electrolyte gas sensor or even biological sensors.

1. Introduction

Graphene is becoming an attractive nanostructure with many remarkable electronic, optical, chemical, and mechanical properties since its discovery [1, 2]. As a unique two-dimensional nanomaterial, graphene has extremely large surface-to-volume ratio, shows exceptionally high electron mobility at room temperatures, and is sensitive to molecular adsorption [312]. Graphene is also a biocompatible sensing material [8, 13]. Schedin et al. [14] have demonstrated that graphene could even detect individual molecules and allows high signal-to-noise ratio due to the fact that graphene carrier mobility is very high. Namely, the high conductivity and few crystal defects enable a few extra electrons to cause notable changes in carrier concentration of graphene and sensor signal. It is worth mentioning that the extremely high breaking strength ~130 GPa allows graphene to be suspended across a trench about micron size in width [15, 16]. In recent years, Cheng et al. [16] have demonstrated a suspended graphene sensor in aqueous solution in comparison with that of nonsuspended graphene sensor, to display an improved signal-to-noise ratio.

Having a pH sensor which can reliably measure values in the range of 7.35–7.45 is extremely important in medicine as normal human body has pH values in this range and changes in this value can indicate a potential health hazard. In this work, we demonstrate two kinds of graphene film to serve as channel of field effect transistor (FET) used as pH sensors, in which graphene films cover microtrench to construct liquid ion container inhaling pH buffer solution. Growth morphology and pH sensing properties of both continuous few-layer graphene (FLG) and quasi-continuous monolayer graphene (MG) channels are compared and the type of graphene suitable for high resolution pH value testing is investigated.

2. Experiment

Graphene used here is synthesized in our laboratory on copper and nickel foils using low pressure chemical vapor deposition (CVD) method [17]. A schematic of the graphene channel liquid container FET with microtrench is illustrated in Figure 1(a).

The SiO2 layers between the source and drain electrodes are etched down to form a microtrench. Graphene was cleaned with deionized (DI) water, dried in nitrogen, and transferred by the polymer-support transfer method [1821] upon the top of the electrodes, thus bridging the source and drain electrodes. The substrate used here is an N+ doped silicon substrate with a 300 nm thick SiO2 layer above. The flowchart of the sensor fabrication is depicted in Figure 1(b). Firstly, we have fabricated interdigital source and drain electrodes on microtrench using lift-off and etching process in steps (1) to (5). The wet etching method was used to form microtrench. Secondly, the graphene film was grown and transferred to the PDMS film in steps (6) to (8). Finally, we achieved the graphene channel liquid container FET after the microtrench was covered by graphene film in steps (9) and (10).

The pH value measurements setup is shown in Figure 2. Buffer solutions with pH from 13 to 7 were obtained by diluting alkaline solution. A drop of buffer solution is then dispersed on graphene layer. A semiconductor parameter analyzer (Keithley Instruments, Inc., 4200 SCS) was used to monitor the current between source and drain of the suspended graphene channel FET during the test. Various concentrations of buffer solutions were introduced to the trench and graphene manually via injection at the humidity of 26% and temperature of 25°C. The DI water was introduced to trench and graphene for recovery process. The crystal structure of the graphene is investigated using scanning electron microscopy (SEM) (S-4800 field emission scanning electron microscope). Raman spectra were collected by Horiba Jobin Yvon HR 800 using a 514 nm laser excitation. Raman spectra were fitted by Voigt function using peak fitting function of Origin 9.0.

3. Results and Discussion

3.1. Characterizations of Two Kinds of Graphene

Graphene is obtained on two kinds of substrates with different surface morphology and structure. SEM analysis is used to determine the morphology and size of as-prepared graphene. Graphene grown on nickel substrate is a large area of continuous film with some white fold on surface as shown in Figure 3(a). The quality and thickness of the graphene were further measured by Raman spectrum (Figure 3(a) inset). The G band and the 2D band have peaks at around 1580 cm−1 and 2667 cm−1, respectively. The as-prepared graphene has good quality and low defect density because it contains obvious characteristic 2D peak and invisible D peak (defect peak around 1350 cm−1). Few-layer graphene (FLG) on nickel is found to have less than 10 layers, because the ratio is about 0.5. Graphene grown on copper substrate is quasi-continuous film composed of high density ordered hexagonal single crystal graphene domain as shown in Figure 3(b), in which diagonal size is greater than 100 microns. The G band and the 2D band have peaks at around 1584 cm−1 and 2663 cm−1, respectively. The ratio is about 2.5 (Figure 3(b) inset). These results confirmed that the graphene on copper is single crystal and monolayer graphene (MG) without defect peak. Both continuous FLG and quasi-continuous MG (greater than 100 μm) can cover the microtrench and bridge source and drain electrodes, because the width of microtrench is less than 20 μm. White interdomain and fold are clearly visible when quasi-continuous MG film covers microtrench as shown in Figure 3(c).

3.2. pH Value Measurement

Continuous FLG film is used in large range pH value experiment. When pH buffer solution flows into the trench, the ions in liquids (charged molecules) would be bound to the double sides of suspended FLG surface to change the conductance of graphene, which in turn modulates the source-to-drain current. The source-to-drain current response with time in pH buffer solution under different pH value is shown in Figure 4(a). The changed instantly when the pH buffer solution was inhaled into the microtrench. Altogether it takes about 1 to 4 seconds to reach a relatively stable value. It follows a typical exponential decay process, with a final equilibrium status between adsorption and desorption of OH, which is the main cause in absorption. The response time constant is estimated to be about 3.11 s, 3.55 s, 3.56 s, and 3.7 s for a testing solution of pH values of 7.0, 10.0, 11.0, and 13.0, respectively.

The initial value is not at the same starting point because the desorption of OH is not complete. Sensitivity , which is defined as , clearly shows contrast at each pH value and is shown in Figure 4(b). Sensitivity increases almost linearly with the increase of pH value of the solution suggesting that the OH absorption of the graphene is still far away from saturation in the tested region of curve, so we could look forward to extending the linear range. The OH group has an unpaired electron and would trap electrons [8, 9] from FLG. Comparing with reported p-type channel of SiNWs or CNTs [16, 2224], the of the FLG channel decreased with pH values increasing, which further confirms that the prepared FLG channel of FET sensor is n-type. The are 4.75%, 24.65%, 31.63%, and 45.1%, corresponding to pH values of 7.0, 10.0, 11.0, and 13.0, respectively. The pH value resolution of continuous FLG film is 0.1.

In order to investigate pH value resolution of quasi-continuous MG channel liquid container FET, small range experiment between pH = 7.00 and pH = 8.00 was carried out as shown in Figures 5(a) and 5(b). The takes about 10 to 25 seconds to reach a relatively stable value when the pH buffer solution was introduced into the microtrench and response time constant is estimated to be about 22.42 s, 11.72 s, and 14.82 s for pH values of 7.35, 7.59, and 7.86, respectively. Sensitivity increases almost linearly with the increase of pH value, and are 34.5%, 47.6%, and 57.4%, corresponding to pH values of 7.35, 7.59, and 7.86, respectively. For FLG channel, the output sensitivity of FET is 4.75% when the pH = 7.0. Notably, for the quasi-continuous MG channel, the output sensitivities are from 34.5% to 57.4% when the pH value is between 7.00 and 8.00, which increase nearly one order of magnitude. The reason is that with fewer defects the MG can adsorb more measured molecules and ions than the FLG in the similar ambient. MG is suitable for normal human body pH values testing, which are 7.35~7.45. The pH value resolution of quasi-continuous MG film is 0.01.

4. Conclusions

We have demonstrated a simple method to fabricate both FLG and MG graphene channel liquid container field effect transistor pH sensors. An interdigital pattern microtrench, which is used as microcontainer for inhaling liquid ion, was fabricated on SiO2 layer. FLG is less than 10 layers and MG is single crystal and monolayer. Our results show that FLG graphene channel FET has faster response than that of MG after adsorption of the measured molecule and ion at the room temperature. Both resolution and output sensitivities of MG on pH value are one order of magnitude higher than those of FLG. The device can be applied to other fields as gas sensor and even biological sensors. MG is suitable for high resolution normal human body pH testing. Most importantly, the concept of selecting the appropriate structure of graphene according to the different analyte testing requirements may provide a new insight about a new approach for graphene sensor.

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.

Acknowledgments

This work was financially supported by grants from the National Natural Science Foundation of China (nos. 91123018, 61172040, and 61172041), Shaanxi Natural Science Foundation (2014JM7277), and the Fundamental Research Funds for the Central Universities.