Location of the maximum number of false beats that can be included in a five-minute segment before failure, with LF, HF, and LF/HF (n.u.) recorded in the final “successful” PSD estimate.

MethodEctopic beats (individual)Ectopic beats (group)Missed trigger (individual)Missed trigger (group)
Max. false beatsLF/HFLFHFMax. false beatsLF/HFLFHFMax. false beatsLF/HFLFHFMax. false beatsLF/HFLFHF

True value0.470.290.630.470.290.630.470.290.630.470.290.63
“Baseline”230.550.320.58350.560.320.58200.570.330.57320.640.350.55
“Rules” edited RR intervals170.640.330.5260.610.320.53180.690.340.49160.760.360.47
CSI00.770.380.5000.750.370.5010.780.390.5010.750.380.50
OUGP40.450.310.6840.640.370.5870.750.420.5620.890.450.51
EMD80.280.220.7640.500.320.6590.620.370.6040.450.290.66
LS (all points)70.340.240.7020.370.250.6830.380.250.6620.520.310.61