Research Article

Numerical Simulation Study on the Development Effect of Gravity Fire Flooding by Vertical Well Sidetracking

Table 3

Recovery factor under different combination of main control factors.

The length of sidetracking in vertical wellsPerforated positionRecovery ratio (%)

3/71/30.1860 000250.0055.87
3/72/30.163 000357.1453.74
3/710.2436 000416.6754.78
4/71/30.290 000250.0046.36
4/72/30.1890 00083.3345.45
4/710.224 000625.0042.25
5/71/30.1242 000357.1433.62
5/72/30.1821 000238.0925.73
5/71/30.29 00083.3337.32