Research Article
Analysis of the Oceanic Wave Dynamics for Generation of Electrical Energy Using a Linear Generator
Table 5
The parameters of the PMLG.
| Name of the item | Value | Unit |
| Pole pitch of translator and stator | 4 | cm | Pitch factor of pole shoe | 0.4 | | Turn number of copper coil | 70 | Turns | Number of coils in a winding | 2 | | Winding factor | 0.6 | | Velocity/speed of the translator | 0–1.5 | m/s | Air gap length | 2 | mm | Internal resistance of windings | 0.3 | Ω | Load resistance | 2–25 | Ω | Maximum power (depends on some factors) | 175–692 | W |
|
|