Research Article
Power Consumption: Base Stations of Telecommunication in Sahel Zone of Cameroon: Typology Based on the Power Consumption—Model and Energy Savings
Table 6
Proposal of energy savings on the lighting aspect and air conditioning of the CRTV Maroua site.
| Period | Characteristics of the site |
| 8:00 am–6:00 pm | Widening of the climatic range by 2°C of the FM and RFI rooms, the lighting lamps are switched off | 6:00 am–10:00 pm | Widening of the climatic range by 2°C of the FM and RFI rooms, the lighting lamps are switched on | 10:00 pm–6:00 am | Widening of the climatic range by 3°C of the FM and RFI rooms, the lighting lamps are switched on | 6:00 am–8:00 am | Widening of the climatic range by 3°C of the FM and RFI rooms, the lighting lamps are switched off |
|
|