Research Article

Modal Analysis and Flow through Sectionalized Pipeline Gate Valve Using FEA and CFD Technique

Table 3

First five modes of linear vibration.

Mode shape: 1
Value = 88,8406 Hz

Resultant amplitude: 1.058e − 01 mm
Node: 1292
Mode shape: 2
Value = 97,872 Hz

Resultant amplitude: 6.840e − 02 mm
Node: 1427
Mode shape: 3
Value = 149,634 Hz

Resultant amplitude: 1.954e − 01 mm
Node: 12218
Mode shape: 4
Value = 160,331 Hz

Resultant amplitude: 1.560e − 01 mm
Node: 12110
Mode shape: 5
Value = 286,782 Hz

Resultant amplitude: 2.024e − 01 mm
Node: 11840