Research Article

Computational Fluid Dynamics Simulation Assessment of Inlet Configuration Influence on Enhancing Swirl Flow Microbubble Generator Performance

Table 3

The pressure drop of different inlet-type microbubble generators.

Inlet velocity (m/s)Pressure drop (kPa)
Single inletDouble inletTangent-circle inlet

11.715.863.08
27.0826.3114.29
316.3162.8833.96
429.68116.9562.23