Research Article

Relating Corroded Seven-Strand, Posttensioned Cable Cross-Sectional Properties to Load Capacity

Table 1

Best-fit curve properties for single wire area and minimum second-moment short axis diameter, respectively.

Method⁢Minimum wire area (all samples)Minimum wire diameter (all samples)
Min. area range capacity for wire area of 0 mm2 (kN)Max. area range capacity for wire area of 20.27 mm2 (kN)Min. diameter range capacity for wire diameter of 0 mm (kN)Max. diameter range capacity for wire diameter of 5.08 mm (kN)

Linear66.109297.350.85−6.19286.670.89
Poly
Order 2
18.75273.660.9−39.54279.130.89
Poly
Order 3
19.73273.940.944.12273.840.9
Power0291.950.90291.630.87