Research Article
Relating Corroded Seven-Strand, Posttensioned Cable Cross-Sectional Properties to Load Capacity
Table 1
Best-fit curve properties for single wire area and minimum second-moment short axis diameter, respectively.
| Method | Minimum wire area (all samples) | Minimum wire diameter (all samples) | Min. area range capacity for wire area of 0 mm2 (kN) | Max. area range capacity for wire area of 20.27 mm2 (kN) | | Min. diameter range capacity for wire diameter of 0 mm (kN) | Max. diameter range capacity for wire diameter of 5.08 mm (kN) | |
| Linear | 66.109 | 297.35 | 0.85 | −6.19 | 286.67 | 0.89 | Poly Order 2 | 18.75 | 273.66 | 0.9 | −39.54 | 279.13 | 0.89 | Poly Order 3 | 19.73 | 273.94 | 0.9 | 44.12 | 273.84 | 0.9 | Power | 0 | 291.95 | 0.9 | 0 | 291.63 | 0.87 |
|
|