Research Article
Water Pollution and Water Quality Assessment of Major Transboundary Rivers from Banat (Romania)
Table 5
Water quality status and WQI values at sampling stations from the Bega River.
| Water quality parameters (unit) | Water sampling station | Timişoara | Otelec | Max. | Min. | Mean | Max. | Min. | Mean |
| DO (%) | 148.9 | 44.9 | 85.6 | 136.9 | 23.8 | 61.9 | pH (U pH) | 7.8 | 7 | 7.4 | 7.7 | 6.9 | 7.3 | BOD5 (mg O2/L) | 3.8 | 0.8 | 1.8 | 10.3 | 3.2 | 5.7 | Temperature (°C) | 23.9 | 1.4 | 12.2 | 24.7 | 1.5 | 13.1 | Total P (mg P/L) | 0.395 | 0.026 | 0.117 | 0.881 | 0.161 | 0.418 | N-NO2− (mg N/L) | 0.041 | 0.004 | 0.013 | 0.268 | 0.011 | 0.056 | Turbidity (mg/L) | 132.1 | 5.7 | 30.1 | 134.8 | 5.2 | 28.9 | Overall WQI | 65 | 80 | 84 | 64 | 69 | 68 | Class | III | II | II | III | III | III | Water quality status | Med. | Good | Medium | Water quality concern | Marginal concern | Lowest concern | Marginal concern |
|
|
Source. Data processed by the Banat Water Basin Administration (ABAB) Archives, Timişoara.
|