Research Article

Synthesis of Modified Magnetic Graphene Oxide with Mesoporous Silica for Extraction of the Pharmaceutical Compound Quercetin

Table 4

Comparison of the proposed method with some different methods to determination of quercetin.

MethodsSampleLOD (μg L−1)LDR (μg L−1)RSD (%)Reference

GO/Fe3O4/HPLC-UVTea and urine0.8 (μg L−1)3–1500 (μg L−1)≤5.6[18]

d-MSPE1/Fe3O4/SiO2/HPLC-UVFruit juices and vegetables0.18 (μg L−1)0.6–500 (μg L−1)0.80[19]

DLLME-SFO2/UV-VisApple, onion, and tomato3.02 (μg L−1)15.10–151.00 (μg L−1)2.8[20]

MIP-SPME3/HPLC-UVBlack tea
Green tea
Coffee
9.94 (μg L−1)50–100.000 (μg L−1)2.3[21]

MSPE (MACC4)/UV-VisOnion1.40 (μg L)16.8–3358 (μg L−1)<10[22]

SPME (CW/TPR5)
HPLC-UV
Food sample9.94 (μg L−1)50–100 000 (μg L−1)2.3[23]

MSPE (Fe3O4@GO@mSiO2)/UV-VisSpinach
Green pepper
Red onion
Dill weed
5.2 (μg L−1)20–800 (μg L−1)3.78This work

1Magnetic solid-phase extraction. 2Dispersive liquid-liquid microextraction based on the solidification of the coating organic. 3Molecularly imprinted polymer solid-phase microextraction. 4Magnetic-activated carbon cloth. 5Carbowax/templated resin.