Precision, accuracy, recovery, and matrix effect of ephedrine, gastrodin, and liquiritin in rat plasma.
| Analytes | Added C (ng/mL) | Extraction recovery (%) (n = 6) | Matrix effect (%) (n = 6) | Intraday (n = 5) | Interday (n = 15) | Stability (n = 6) | Found C (ng/mL) | RSD (%) | RE (%) | Found C (ng/mL) | RSD (%) | RE (%) | Short-term stability (%) | Long-term stability (%) | Freeze-thawstability (%) |
| Ephedrine | 5 | 86.88 ± 1.08 | 100.4 ± 3.83 | 4.57 ± 0.52 | 11.5 | −8.60 | 4.48 ± 0.60 | 13.4 | −10.4 | 89.23 ± 2.63 | 87.43 ± 5.26 | 87.15 ± 3.81 | 40 | 87.47 ± 2.35 | 96.40 ± 2.45 | 41.3 ± 2.8 | 6.84 | 3.33 | 37.6 ± 3.3 | 8.89 | -6.0 | 91.40 ± 3.05 | 90.68 ± 2.43 | 90.04 ± 4.07 | 200 | 92.32 ± 3.69 | 96.76 ± 3.82 | 209.8 ± 10.3 | 4.93 | 4.90 | 205.6 ± 8.81 | 4.28 | 2.82 | 91.27 ± 5.22 | 91.67 ± 1.07 | 90.66 ± 6.42 |
| Gastrodin | 150 | 89.25 ± 4.07 | 96.59 ± 1.26 | 162.7 ± 10.2 | 6.28 | 8.4 | 161.3 ± 18.0 | 11.1 | −7.56 | 89.29 ± 3.99 | 90.11 ± 3.78 | 89.88 ± 2.33 | 600 | 87.98 ± 5.20 | 96.72 ± 3.57 | 580.3 ± 20.6 | 5.15 | −3.3 | 587 ± 35.8 | 6.09 | −2.12 | 90.69 ± 5.33 | 90.85 ± 1.04 | 91.58 ± 1.27 | 2000 | 90.14 ± 3.22 | 95.15 ± 0.78 | 1989 ± 66.6 | 3.35 | −0.53 | 2016 ± 87.2 | 4.32 | −0.80 | 91.80 ± 4.01 | 93.11 ± 3.78 | 93.33 ± 2.63 |
| Liquiritin | 15 | 88.75 ± 6.08 | 98.17 ± 3.69 | 16.1 ± 1.7 | 10.7 | 7.56 | 16.4 ± 1.5 | 9.33 | 9.11 | 89.16 ± 1.28 | 89.23 ± 4.65 | 88.29 ± 5.96 | 75 | 90.49 ± 3.83 | 97.71 ± 1.54 | 70.7 ± 3.3 | 4.74 | −5.78 | 76.4 ± 1.9 | 2.46 | 1.82 | 91.72 ± 6.47 | 91.87 ± 1.93 | 90.59 ± 4.22 | 400 | 90.81 ± 1.73 | 99.87 ± 7.01 | 390.8 ± 15.5 | 3.97 | −2.3 | 389.5 ± 15.0 | 3.86 | −2.63 | 92.13 ± 1.91 | 93.33 ± 5.74 | 92.70 ± 2.91 |
|
|