Research Article

Preparation of Molecular Imprinted Polymer Based on Chitosan as the Selective Sorbent for Solid-Phase Microextraction of Phenobarbital

Table 3

Comparison with reported methods for the determination of phenobarbital

Extraction methodDetectionLinear range (μg·mL−1)LOD (ng·mL−1)Recovery (%)Qh (μg·g−1)RSD (%)References

SPMEaHPLC-UV0.0005–50.321022.9[5]
MIS-SPEbHPLC-UV10–1001000041–75[28]
SFODMEcHPLC-UV0.002–0.3195.8–98.84.4[3]
MIPs-GSCDsdSpectrofluorometer9.2 × 10−5–0.0080.023-7.3[29]
SPMEaGC-MS0.25–2515094.6–106.04.2–7.7[34]
SPMEaGC-MS0.2–402006.3–7.7[24]
MMIPeHPLC-UV1–80812.82[27]
SBSEfHPLC-UV0.08–408072–785.2–7.6[35]
SPME-MIPgHPLC-UV0.01–47.5092.5–98.0112.952.4–4.2This work

aSolid-phase microextraction. bMolecularly imprinted silica—solid-phase extraction. cSolidified floating organic drop microextraction. dMolecularly imprinted polymers—green source carbon dots. eMagnetic molecularly imprinted polymer. fStir bar sorptive extraction. gSolid-phase microextraction molecularly imprinted polymer. hAdsorption capacity.