Research Article

Determination of Cefoperazone Sodium in Presence of Related Impurities by Linear Support Vector Regression and Partial Least Squares Chemometric Models

Table 3

Statistical comparison of the two proposed PLSR and linear SVR chemometric methods against the reported HPLC method for analysis of CEF in pharmaceutical formulations.
(a) Cefobid vial

ParametersPLSRLinear SVRReported HPLC method

Mean102.77100.30102.85
SD0.8981.0311.424
Variance0.8071.0632.027
666
Student’s -test (2.228)0.9070.006
-test (5.050)2.5131.907

(b) Cefoperazone vial

ParametersPLSRLinear SVRReported HPLC method

Mean98.1799.3399.40
SD1.0780.9931.317
Variance1.1610.9851.736
666
Student’s -test (2.228)0.1080.914
-test (5.050)1.2231.327

The values between parenthesis are corresponding to the theoretical values of and ().