Variance analysis of orthogonal experiment.
| Factor test number | Inlet wind speed (m/s) | Discharge distance (mm) | Average electric field intensity (kv/cm) | Interaction | Dust removal efficiency (%) |
| 1 | 5.45 (1) | 40 (1) | 3.0 (1) | (1) | 93.84 | 2 | 5.45 (1) | 60 (2) | 3.6 (2) | (2) | 95.23 | 3 | 5.45 (1) | 80 (3) | 4.2 (3) | (3) | 96.48 | 4 | 10.33 (2) | 40 (1) | 4.2 (3) | (2) | 94.31 | 5 | 10.33 (2) | 60 (2) | 3.0 (1) | (3) | 93.32 | 6 | 10.33 (2) | 80 (3) | 3.6 (2) | (1) | 94.26 | 7 | 14.41 (3) | 40 (1) | 3.6 (2) | (3) | 91.94 | 8 | 14.41 (3) | 60 (2) | 4.2 (3) | (1) | 92.46 | 9 | 14.41 (3) | 80 (3) | 3.0 (1) | (2) | 90.31 | K1 | 285.55 | 280.09 | 277.47 | 280.56 | | K2 | 281.89 | 281.01 | 281.43 | 279.85 | K3 | 274.71 | 281.05 | 283.25 | 281.74 | Sj | 20.27 | 0.20 | 5.82 | 0.61 | |
|
|