Research Article

Critical Hydraulic Eccentricity Estimation in Vertical Turbine Pump Impeller to Control Vibration

Table 2

Details of mesh statistics of four test cases.

MeshBell mouthImpellerBowlColumn pipeTotal nodes (million)Head (m)Absolute deviation with test data (%)

Mesh 10.0170.230.310.120.6822.6ā€”
Mesh 20.020.2650.3650.170.8223.12.2
Mesh 30.02870.320.4150.2060.9723.51.7
Mesh 40.0330.3750.470.2351.1223.60.5