Research Article

Utilization of Open-Source OpenFOAM Code to Examine the Hydrodynamic Characteristics of a Linear Jet Propulsion System with or without Stator in Bollard Pull Condition

Table 7

Thrust force calculated for the linear jet system with a stator.

Pressure thrust for rotorViscous thrust for rotorPressure thrust for duct & statorViscous thrust for duct & statorTotal thrust

0292.391-2.510634.3901-0.749323.521241.37154
0.2246.086-3.231340.9112-2.055281.711241.19429
1.1199.053-3.71068.00042-11.22192.127370.81451
2192.865-4.2118-67.949-23.2697.449240.41313
3107.457-5.6565-143.23-44.31-85.74476-0.3635