Research Article

Utilization of Open-Source OpenFOAM Code to Examine the Hydrodynamic Characteristics of a Linear Jet Propulsion System with or without Stator in Bollard Pull Condition

Table 13

Torque force calculated for the linear jet system in bollard pull mode.

Type of system (rpm)Pressure torque for rotorViscous torque for rotorTorque10

Without stator600.286630.00210.2891.5298949915.2989
60010.60280.044310.650.564215275.64215
90024.09760.091624.190.569710015.6971

With stator600.286650.00210.2891.5300121615.3001
60012.26040.05212.310.652467986.52468
90026.18670.136126.320.619962616.19963