Research Article
Design, Modeling, and CFD Analysis of a Micro Hydro Pelton Turbine Runner: For the Case of Selected Site in Ethiopia
Table 11
Validation and performance prediction of Pelton runner.
| Parameters | Unit | Baseline design test cases | Off- design test cases | Published result by Panthee et al. [10] | Published result by Panagiotopoulos et al. [19] |
| Head | m | 47.5 | 53.9 | 100 | 47.5 | 53.9 | 100 | 53.9 | 100 | Flow rate | m3/s | 0.14 | 0.05 | 135% BEP | 0.14 | 0.05 | 135% BEP | 0.05 | 135% BEP | PCD | mm | 500 | 500 | 500 | 400 | 400 | 400 | 400 | 400 | Runner speed | Rpm | 520 | 520 | 520 | 650 | 600 | 1000 | 600 | 1000 | Number of buckets | ā | 18 | 18 | 18 | 18 | 22 | 22 | 22 | 22 | Model efficiency | % | 78.8 | 83.5 | 84.6 | 62.6 | 66.1 | 71.6 | 82.5 | 86.7 |
|
|