Research Article

Numerical Investigation of Velocity Flow Field inside an Impeller Air Model of a Centrifugal Pump with Vaned Diffuser Interactions and Comparison with PIV Measurements

Table 1

Specifications of the pump.

Test conditions

Speed of rotation1710 rpm
Normalized flow rate
FluidAir at

Entry duct

Diameter0.1411 m
Length0.5129 m

Impeller

Inlet radius0.1411 m
Outlet radius  m
Number of blades7
Outlet height  m
Outlet blade angle
Main blade position
Design flow rate  m3/s

Diffuser

Inlet radius0.2736 m
Outlet radius0.3978 m
Number of vanes8
Height0.040 m
Design flow rate0.8 Qn