Research Article

Energy Efficiency and Feasibility Analysis of Solar Power Generation Using Hybrid System of an Educational Institution in Malaysia

Table 2

Summary of types of end load, a total of quantity, rating power, and operating hours for routine activity at MED, CED, EED, and CD.

NoEnd-loadDepartmentQuantityTotal powerAverage operating hours
(kW)(h/year)

1Laboratory equipmentMED102245.17318
CED10052.335430
EED63314.649436
CD3518.321124

2FanMED1130.299708
CED1090.299708
EED1020.299708
CD880.299788

3LightingMED22410.496708
CED13410.496756
EED22500.496804
CD10470.0781432

4Air conditioning (ACSU+WCPU)MED5973.008928
CED1448.6561499
EED89163.6531375
CD1880.113782

5ICT equipmentMED1860.378309
CED850.591495
EED660.361588
CD320.346780

TotalMED3621119.3512,972
CED1649102.3773,888
EED3140179.4583,911
CD122099.1564,906