Research Article

Impact of Different Solar Trackers on Hydrogen Production: A Case Study in Iran

Table 3

The results of different scenarios in the case of not connected to the grid.

ScenarioComponentTotal NPC ($)COE ($/kWh)Ren. Frac (%)Diesel (L)Elec. Prod (kWh/y)Exc. Elec (kWh)Therm. Prod (kWh/y)Exc. Therm. (kWh)Operation (h)H2 prod. (kg/y)CO2 (kg/y)LCOE ($/kWh)LCOH ($/kg)

No
Track
PV (3), FC (1), Batt (1), Conv. (1),
Elec. (1), H2 tank (1)
104420.84955.3418PV (5862)
FC (412)
2596FC (99)
Boil. (3495)
Dump load (2596)
532PV (4381)
FC (1433)
Boil. (7742)
Elec. (2344)
24.5+11000.1277.968

VACTPV (2), FC (1), Batt (1), Conv. (2), Elec. (1),
H2 tank (1)
99980.81249480PV (4847)
FC (356)
1706FC (48)
Boil. (4011)
Dump load (1706)
144PV (4381)
FC (1223)
Boil. (8200)
Elec. (1977)
20.8+12630.11687.743

HACTPV (2), FC (1), Batt (1), Conv. (2), Elec. (2),
H2 tank (1)
118930.97240557PV (4264)
FC (439)
975FC (104)
Boil. (4659)
Dump load (975)
80.3PV (4381)
FC (1509)
Boil. (8463)
Elec. (2369)
25.7+14670.18684.654

TATPV (2), FC (1), Batt (1), Conv. (2), Elec. (1),
H2 tank (1)
115340.94254.8422PV (5403)
FC (340)
2278FC (80)
Boil. (3532)
Dump load (2278)
232PV (4381)
FC (1167)
Boil. (7933)
Elec. (1658)
20.2+11120.157104.577