Research Article
Impact of Different Solar Trackers on Hydrogen Production: A Case Study in Iran
Table 2
Technical information and the price of equipment used.
| Component | Cost ($) | Specifications | Capital | Replacement | Operation and maintenance |
| PV No-track [60] PV VACT [60] PV HACT [60] PV TACT [60] | 1250 1505 2121 2275 | 1125 1355 1909 2048 | 0 | Lifetime: 25 years Derating factor: 80% |
| Wind turbine [61] | 5000 | 4000 | 50 | Type: WES 5 Tulipo Rated power: 2.5 kW AC lifetime: 25 years Hub height: 25 m Cut-in speed: 2 m/s |
| Battery [61] | 1200 | 1100 | 50 | Type: Surrette 6CS25P Lifetime: 9645 kWh |
| Converter [45] | 300 | 300 | 0 | Lifetime: 20 years Inverter efficiency: 95% Rectifier efficiency: 95% |
| Fuel cell [20] | 3000 | 2500 | 0.02 | Lifetime: 40000 h Min. Load ratio: 25% Efficiency: 90% Heat recovery ratio: 25% |
| Electrolyzer [20] | 500 | 250 | 10 | Lifetime: 20 years Min. Load ratio: 0% Efficiency: 85% |
| Hydrogen tank [45] | 574 | 574 | 10 | Lifetime: 25 years Initial tank level: 20% |
| Boiler [50] | — | — | — | Efficiency: 85% Carbon monoxide 6.5 g/L Unburned hydrocarbons 0.72 g/L Particulate matter 0.49 g/L Fuel sulfur converted to PM 2.2% Nitrogen oxides 58 g/L |
|
|