Research Article
Maximum Power Exploitation of Photovoltaic System under Fast-Varying Solar Irradiation and Local Shading
Table 4
Average power and amplitude of algorithms at the operating point (unit: W).
| Time | PF-MPPT | SPF-MPPT | Average power | Amplitude | Average power | Amplitude | 0.0–0.5 s | 182.5 | 10.5 | 181.5 | 12 | 0.5–1.0 s | 305.5 | 29.6 | 308.5 | 30.3 | 1.0–1.5 s | 127.0 | 4.5 | 126.6 | 4.5 | 1.5–2.0 s | 182.7 | 12.1 | 182.5 | 12.5 | 2.0–2.5 s | 330.2 | 25.9 | 334.3 | 26.9 | 2.5–3.0 s | 180.5 | 9.5 | 180.7 | 12.1 | Time | CVT | P&O | Average power | Amplitude | Average power | Amplitude | 0.0–0.5 s | 157.0 | 18.2 | 157.0 | 18.2 | 0.5–1.0 s | 153.8 | 31.7 | 153.8 | 31.7 | 1.0–1.5 s | 129.0 | 2.9 | 129.0 | 2.9 | 1.5–2.0 s | 154.6 | 18.4 | 154.6 | 18.4 | 2.0–2.5 s | 148.3 | 32.1 | 148.3 | 32.1 | 2.5–3.0 s | 153.9 | 17.5 | 153.9 | 17.5 |
|
|